HF-151 Air Driven Liquid Pump for 25,000 psi systems
HF-151 Air Driven Liquid Pump for 25,000 psi systems

HF-151 Air Driven Liquid Pump for 25,000 psi systems

Product Introduction

Examine the HF-151 air-driven fluid amplifier that provides 25,000 psi maximum discharge pressure, 0.153 in³ (4.4 ml) volume per stroke, and 1/4" NPT high-pressure port for process equipment.

Product Information

Model:
HF-151
Actual area ratio:
173
Maximum supply air pressure:
150 psi
Maximum rated output pressure:
25,000 psi / 1,724 bar
displacement per cycle:
0.27 cu. in. / 4.4 mL
facebook
line
Whatsapp
Pinterest
Tumblr
Linkedin

The HF-151 pneumatic liquid booster pump provides air-driven liquid pressurization with a maximum rated output of 25,000 psi (1,724 bar). Its published displacement is 4.4 mL per cycle, and its discharge connection is designated 1/4-inch HP.

For specialist equipment builders and industrial buyers, the HF-151 offers a defined combination of pressure capacity, displacement, and connection sizes. Both continuous and intermittent operation carry the same listed maximum output pressure.

Specify this model for application review when your liquid pressure system requires performance within these published limits.

High-Pressure Capability for Specialist Equipment Projects

Selecting a pump for a high-pressure assembly starts with the required operating pressure and the liquid volume needed at that pressure. The HF-151’s 25,000 psi rating establishes its maximum rated output, while its displacement provides a separate reference for delivery planning.

Potential project evaluations include component pressure test benches, laboratory pressure equipment, and industrial liquid pressure packages. Suitability depends on the working fluid, temperature, required flow, and operating sequence.

For example, a test assembly may have distinct filling and pressurization stages. Therefore, include the volume and time requirements for each stage when submitting the application. This gives the technical review a clearer picture of the complete duty.

Explore our pneumatic liquid booster pumps for related product options.

HF-151 Manufacturer Specifications

The following data applies specifically to the HF-151 configuration.

Parameter HF-151 Specification
Series HF
Model HF-151
Dash number -151
Actual area ratio 173
Maximum air supply pressure 150 psi
Maximum rated output pressure — continuous duty 25,000 psi / 1,724 bar
Maximum rated output pressure — intermittent duty 25,000 psi / 1,724 bar
Displacement per cycle 0.27 cu. in. / 4.4 mL
Air-drive connection 1/2" FNPT
Liquid inlet connection 1/2" FNPT
Liquid outlet connection 1/4" HP

The actual area ratio is listed separately from the model’s dash number. Use the published output rating when documenting the pump’s pressure limit.

A Dedicated HP Outlet for the Discharge Circuit

The HF-151 uses a 1/4-inch HP outlet, while the air-drive and liquid inlet ports are both 1/2-inch FNPT. These designations should appear separately in the equipment connection schedule.

Before selecting discharge fittings, confirm the HP connection details against the product drawing. The listed size alone does not establish the complete mating geometry.

Also, review the pressure rating and fluid compatibility of the downstream tubing, valves, gauges, and other components. Each part must suit the intended system conditions.

On the supply side, confirm the liquid inlet arrangement and available compressed-air capacity. The maximum permitted air supply pressure is 150 psi.

Understanding the 4.4 mL Displacement

The HF-151 has a listed displacement of 4.4 mL per cycle. This describes liquid volume per cycle; it is not a flow rate per minute.

Actual flow depends on operating conditions, including cycle speed, outlet pressure, air supply, and inlet conditions. Consequently, buyers should specify the required delivery at the intended working pressure.

If cycle time matters to your process, provide the target time as well. Request operating data for that duty point so equipment planning is based on the application’s needs.

For further model comparisons, view our air-driven liquid pumps.

Define the Configuration Before Purchase

For OEM projects, include the HF-151 model reference in the equipment specification. Then confirm the wetted materials, seals, operating temperature range, dimensions, and mounting details.

Fluid compatibility requires a specific review. Provide the liquid name and concentration where relevant, together with the operating temperature.

In addition, define the supply scope during quotation. Identify any required accessories, connection components, drawings, manuals, or other documentation. For replacement orders, include the existing pump reference and installation details to support a complete comparison.

Request an HF-151 Technical and Commercial Offer

Send our team your target pressure, required flow, working liquid, available air supply, and operating schedule. Please also state the order quantity, delivery destination, and required delivery date.

A circuit diagram can help clarify the pump’s connection to the rest of the pressure assembly.

Request an HF-151 booster pump quotation to discuss application suitability, outlet connection details, pricing, and lead time.

Recommended products